Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply

Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply
Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply

Liebert GXT2-3000RT230E 3000VA online/pure sinewave Uninterruptible Power Supply

Liebert GXT2-3000RT230E 3000VA on line / pure sine wave Uninterruptible Power Supply. Creates clean consistent power completely protected from external problems. Supplies the full domestic power from the wall.

I used it to protect my entire video edit suite when I had much more expensive equipment. Plenty of run time for maintaining perfect supply or controlled shutdown in case of power outages. Includes network/rs232 card for remote control. Includes rack ears for securing in server rack. Does not include rack mount or rails.

Few scratches, especially on the bottom from installing in rack. I had it in the bottom of the rack so did not have rack mount kit.

Front panel comes off quite easily. See photo of it removed.

Located in Crystal Palace, London. Collection in person very much preferred as it is very very heavy. 3000VA / 2100 watt UPS. Fully tested and working, including duration heavy load tests, voltage sag and surge and noise situations. Unit is ON LINE / double conversion topology, which means it isolates you completely from the mains grid, running from the internal cell at all times - which in turn is being charged.

This is the most comprehensive topology for a UPS and prevents any power problem from filtering through. Can be used as a tower standalone ups, or in a rack.

UPS ready for immediate use. Supplied with 1x power cable.

Internal batteries operate at 72 volts for people looking for project inverters. UK / EU input voltage 220 to 240. Frequency Range, Hz 40 - 70 Hz; Auto Sensing.

Battery Test Type Manual & Automatic. Runtime, Full Load, Watt 5 min. Runtime, Half Load, Watt 16 min. Recharge Time 5 Hrs to 95%. Output Waveform on Battery Sinewave.

Unit Height, inches (mm) 17.0 (430). Unit Width, inches (mm) 3.5 (87). Unit Depth, inches (mm) 24.2 (618). (kg) 69.0 (31.0).

(kg) 78.0 (35.4). Operating Temperature, Minimum °F (°C) 32 (0). Operating Temperature, Maximum °F (°C) 104 (40). Storage Temperature, Minimum °F (°C) 5 (-15).

Storage Temperature, Maximum °F (°C) 104 (40). Relative Humidity 0% to 95%, Non Condensing. (m) Up to 10,000 (3000). Agency Approval cUL Listed, FCC Part 15, Subpart B, Class A, UL 1778, UL Listed.

The UPStation GXT2U on-line single-phase Uninterruptible Power System is available in RackTower (RT). Configuration which can be installed free standing (option included) or rackmounted. The following power ratings: 700VA, 1000VA, 1500VA, 2000VA and 3000VA in 230V - 120V models are also. The main standard features include.

+ True on-line configuration to ensure that the critical load is always supplied with sine-wave, computer. + RackTower construction provides the flexibility required to cover all installations - the same unit can be. Rackmounted or used as minitower (options included). «Only 2U high up to 3000 VA (including battery) - all units are 19 wide to fit rack enclosures. « Higly increased back-up time: up to 17 minutes at full load. + Communications interface providing both opto-isolated shutdown signals and RS232 protocol. This allows the GXT2U to communicate with a wide range of computers such as the.

AS400 and other devices, providing a means to interrogate the UPS remotely in order to monitor status. And alarms, or even to remotely control UPS operation.

+ Compatible with Multilink Software: it's included in CD format or it can be downloaded free of charge. This software allows "in-band" single or multiple server. Shutdown through serial communications or SNMP. It can be used across mixed operating platforms and.

Network topologies, allowing your power protection software to expand as your network develops. + Communication cable is included for use with Multilink Software.

+ Compatible with Intellislot SNMPWEB Card: a user installable internal adapter that provides the. Hardware and software necessary to communicate with any IP based network using Ethernet. Connection to the network is made by a cable provided by the customer. Output parameters and alarms user configurable: it's possible to select the output voltage out of four. Different ratings(200/208/220/230/240V), to enable or disable Auto Restart, to select output frequency 50.

Or 60Hz - GXT 2U acts as Frequency Converter, to modify the low battery warning, to select how often. You want the automatic test to occur or to disable it. + External 2U battery cabinets available - 48V 2U battery cabinet for 700, 1000, 1500, 2000 VA models.

And 72V 2U battery cabinet for 3000VA model. + Hot swappable and easy user replaceable batteries allow batteries to be easily replaced on site without. Removing the UPS from the rack enclosure, reducing the cost of ownership and minimising the time for. Wich the critical load is unsupported.

+ Wide input voltage window: 119/159 to 280V AC variable based upon output load. «Input cables: The 230V 3000VA is supplied with the input cable. The other 230V models are not supplied. With the input cable (use the cable provided with your server) - 120 models are all supplied with US.

+ Microprocessor control of the system to monitor input, output and battery conditions and respond. + Manual transfer to bypass facility via front panel controls - Bypass assures continuity of power to critical. Loads during system problems or maintenance. + External bypass - Liebert Micro POD or the new Liebert 2U POD allow you to manually transfer your. Connected equipment to utility power via a maintenance bypass switch, permitting scheduled maintenance.

Or UPS replacement without power disruption - Both all are available in 10A and 16A ratings. + Input transient suppression and filtering to help prevent damage to the load from mains-borne noise or. Spikes, even whilst on bypass. Pulse width modulated (PWM) inverter to provide a voltage and frequency regulated supply to the load.

Over all rated load, mains and batery conditions. Power-factor-correcting input converter stage to reduce the input current distortion. Input and output RFI filtering to ensure that the electrical noise seen by the load (and the mains supply).

Is reduced to accetable levels. Battery test feature automatically carried out on start-up and thereafter by-weekly to indicate when. Batteries need to be replaced.

The battery test can also be carried out manually. Audio-Visual display panel to provide easy to read UPS, load and battery status indications. Simple output on/off control via push buttons on the front of the unit.

Variable speed cooling fan to ensure system optimum operating temperature is maintained. Rack Shelves, allow mounting of the UPS into telecom/relay racks. The RS500 is designed to allow. Flush-mounting of the UPS into 19 wide telecom/relay(single mounting rail type) racks. Designed to allow centre mounting of the UPS into 19 wide telecom/relay (single mounting rail type).

The RS700 is designed to allow flush mounting of the UPS into 24 wide telecom/relay single. The RS800 is designed to allow centre mounting of the UPS into 24 wide.

Telecom/relay (single mounting rail type) racks. Rack Slide Kits for GXT 2U Models, telescoping slide rails that mount to the sides of the rackmount.

UPS to facilitate installation into a rackmount enclosure. RS18-26 rack slides are adjustable from 18 to 26.

Inches - RS24-32 rack slides are adjustable from 24 to 32 inches. GXT 700 and 1000VA in Mini Tower configuration will be still available to satisfy specific clients needs. CE Mark: GXT 2U 230V models are all CE marked - 120V models are UL and c-UL listed. 700/490 10007 700 1500/1050 2000 / 1400 3000 2100.

230 VAC nominal, (119 to 280 VAC Variable based upon output load). Frequency 40 - 70 Hz; Auto Sensing. Voltage 200/208/220/230/240 (user configurable) VAC; plus/minus3%. Frequency 50 Hz or 60 Hz (user configurable).

Type Valve-regulated, non spillable, flame retardant, lead acid. China Storage Battery / CSB FR 1270 F2. 24 minutes 13 minutes 10 minutes 10minutes 10 minutes. 24 minutes 25 minutes 20 minutes 14 minutes 16 minutes. 5 Hours to 95% capacily after full discharge into 100% load.

(4) EN 60320/C13 (4) EN 60320/C13 - (1). Dimensions w x d x h (mm). 9(2U) x 546 x 432 (19°) 89(20) x 615 x 432 (19°). 268 X 692 X 585. 22 23 23 25 34.

27 27 27 284 354. 0°C 10 +40°C (+32°F 10 +104°F).

15°C 10 +50°C +5°F (0 +122°F). N° of input cables included Use the cable provided with your server I 7 (16 Amp). Rack Mounting support _ (Please look for detalls into this document) No. Safety EN 50091-1-1, CE compliance mark, for both Low Voltage and EMC Directives. EN 61000 4-2, 4-3, 4-4, 4-5.